CE,ROHS 50W Dual Output Switching Power Supply
50W Dual Output Switching Power Supply D-50
Featues:
1. Universal AC input/ full range
2. Protections: short circuit/ overload/ over voltage
3. Cooling by free air power on
4. 100% full load burn-in test
5. LED indicator for power on
6. All using 105°c long life elctrolytic capacitors
7. Withstand 300VAC surge input for 5 second
8. High operating temperature up to 70°c
9. Withstand 5G vibrtion test
10. High efficiency, long life and high reliablity
11. 3 years warranty
12. Isolated output & GND for CH1, CH2
Model Specification | D-50A | D-50B | ||
CH1 | CH2 | CH1 | CH2 | |
DC output voltage | 5V | 12V | 5V | 24V |
Output voltage error (Note2) | ±2% | ±5,-8% | ±2% | ±8% |
Rated output current | 6A | 2A | 6A | 1A |
Output current rage | 1-6A | 0.3-2A | 1-6A | 0.2-1A |
Wave and noise(Note3) | 50mVp-p | 100mVp-p | 50mVp-p | 100mVp-p |
Inlet stability(Note4) | ±0.5% | ±1% | ±0.5% | ±1% |
Load stability(Note5) | ±0.5% | ±0.5% | ±0.5% | ±8% |
DC output power | 54W | 54W | ||
Efficiency | 73% | 73% | ||
Adjustable range for DC voltage | CH1+10,-5% | CH1+10,-5% | ||
AC input voltage range | 85~132VAC/170~264VAC;selected by switch 47~63Hz;240-370VDC | |||
Input current | 1.3A/115V 0.65A/230V | |||
AC impulse current | Cold-start current 18A/115V 36A/230V | |||
Leakage current | <0.5mA/240VAC | |||
Overload protection | 105%~150% Type:FOLDBACK Cut off output Reset. auto recovery | |||
Over-voltage protection | …… | |||
High-temperature protection | …… | |||
Temperature coefficient | ±0.03%°C(0~50°C) ON+5V OUTPUT | |||
Setup rise hold up time | 200ms,50ms,30ms | |||
Vibration | 10~500Hz,2G 10min./1cycle,Period for 60min,Each axes | |||
Withstand voltage | Input and output interval:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC | |||
Isolation resistance | Input and output interval,Input and enclosure,Output and enclosure:0500VAC/100M Ohms | |||
Working temperature and humidity | -10°C~+60°C,20%~90%RH | |||
Store temperature and humidity | -20°C~+85°C,10%~95RH | |||
Overall dimension | 159*97*38mm | |||
Weight | 0.52Kgs | |||
Safety standards | Meet UL1012 | |||
EMC standards | …… | |||
Note:1.The testing condition for the parameter above is:230VAC input, rated load,25°C 70%Rh,Humidity2.Error,include the setting error, line stability and load stability.(Note:5)3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.5.Load stability test: The load is from 0% to 100%,others 60%.6.C2,3,11must be knocked down. |
CE,ROHS 50W Dual Output Switching Power Supply